2018 IEBC International Existing Building Code

Saved in:
Bibliographic Details
Corporate Author: International Code Council
Format: Books Print Book
Language:English
Published: Country Club Hills, IL : International Code Council, Inc., 2017.
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000cam a2200000Ii 4500
001 on1022947212
003 OCoLC
005 20210630113900.0
008 180213t20172017ilua 000 0 eng d
019 |a 1000225400  |a 1000578774  |a 1001333799 
020 |a 9781609837525  |q (soft cover edition) 
020 |a 1609837525  |q (soft cover edition) 
020 |z 9781609837518  |q (loose leaf edition) 
028 5 0 |a 3550S18 
035 |a (OCoLC)1022947212  |z (OCoLC)1000225400  |z (OCoLC)1000578774  |z (OCoLC)1001333799 
040 |a AP5  |b eng  |e rda  |c AP5  |d BTCTA  |d YDX  |d NFP  |d AP5  |d OCLCO  |d OCLCQ  |d OCLCO  |d OCLCF  |d DUNPL  |d OMB  |d DGW  |d PCB 
050 4 |a KF5701  |b .S624 2017 
082 1 4 |a 343.07869 INT  |2 23 
245 0 0 |a 2018 IEBC :  |b International Existing Building Code /  |c International Code Council. 
246 3 1 |a 2018 International Existing Building Code 
246 3 |a IEBC, International Existing Building code 2018 
246 3 1 |a International Existing Building Code 2018 
264 1 |a Country Club Hills, IL :  |b International Code Council, Inc.,  |c 2017. 
264 4 |c Ã2017 
300 |a xviii, 298 pages :  |b illustrations ;  |c 28 cm 
336 |a text  |b txt  |2 rdacontent 
337 |a unmediated  |b n  |2 rdamedia 
338 |a volume  |b nc  |2 rdacarrier 
505 0 |a 1. Scope and administration : Part 1. Scope and application -- Part 2. Administration and enforcement : Department of building safety ; Duties and powers of code official ; Permits ; Construction documents ; Temporary structures and uses ; Fees ; Inspections ; Certificate of occupancy ; Service utilities ; Board of appeals ; Violations ; Stop work order ; Unsafe buildings and equipment ; Emergency measures ; Demolition -- 2. Definitions -- 3. Provisions for all compliance methods : Administration ; General provisions ; Structural design loads and evaluation and design procedures ; In-situ load tests ; Accessibility for existing buildings -- 4. Repairs : General ; Building elements and materials ; Fire protection ; Means of egress ; Structural ; Electrical ; Mechanicals ; Plumbing -- 5. Prescriptive compliance method : General ; Additions ; Alterations ; Fire escapes ; Windows and emergency escape opening ; Change of occupancy ; Historic buildings -- 6. Classification of work : General ; Alteration, level 1 ; Alteration, level 2 ; Alteration, level 3 ; Change occupancy ; Additions ; Historic buildings ; Relocated buildings -- 7. Alterations: Level 1 : General ; Building elements and materials ; Fire protection ; Means of egress ; Reroofing ; Structural ; Energy conservation -- 8. Alterations: Level 2 : General ; Building elements and materials ; Fire protection ; Caron monoxide detection ; Means of egress ; Structural ; Electrical ; Mechanical ; Plumbing ; Energy conservation -- 9. Alterations: Level 3 : General ; Special use and occupancy ; Building elements and materials ; Fire protection ; Means of egress ; Structural ; Energy conservation -- 10. Change of occupancy : General ; Special use and occupancy ; Building elements and materials ; Fire protection ; Means of egress ; Structural ; Electrical ; Mechanical ; Plumbing ; Other requirements ; Change of occupancy classification -- 11. Additions : General ; Heights and areas ; Structural ; Smoke alarms in occupancy groups R and I-1 ; Carbon monoxide alarms in groups I-1, I-2, I-4 and R ; Storm shelters ; Energy conservation -- 12. Historic buildings : General ; Repairs ; Fire safety ; Change of occupancy ; Structural ; Relocated buildings -- 13. Performance compliance methods -- 14. Relocated or moved buildings -- 15. Construction safeguards : General ; Protection of adjoining property ; Temporary use of streets, alleys and public property ; Fire extinguishers ; Means of egress ; Standpipes ; Automatic sprinkler system ; Accessibility ; Water supply for fire protection -- 16. Referenced standards -- Appendix A. Guidelines for the seismic retrofit of existing buildings : A1. Seismic strengthening provisions for unreinforced masonry bearing wall buildings : Purpose ; Scope ; Definitions ; Symbols and notations ; General requirements ; Materials requirements ; Quality control ; Design strengths ; Analysis and design procedure ; General procedure ; Special procedure ; Analysis and design ; Detailed building system design requirements ; Walls of unburned clay, adobe or stone masonry -- A2. Earthquake hazard reduction in existing reinforced concrete and reinforced masonry wall buildings with flexible diaphragms : Purpose ; Scope ; Definitions ; Symbols and notations ; General requirements ; Analysis and design ; Materials of construction -- A3. Prescriptive provisions for seismic strengthening of cripple walls and sill plate anchorage of light, wood-frame residential buildings : General ; Definitions ; Structural weaknesses ; Strengthening requirements -- A4. Earthquake risk reduction in wood-frame residential buildings with soft, weak or open front walls : General ; Definitions ; Analysis and design ; Prescriptive measures for weak story ; Materials of construction ; Information required to be on the plans ; Quality control -- A5. Referenced standards -- Appendix B. Supplementary accessibility requirements for existing buildings and facilities : Qualified historical buildings and facilities ; Fixed transportation facilities and stations ; Dwelling units and sleeping units ; Referenced standards -- Appendix C: Guidelines for wind retrofit of existing buildings : C1. Gable end retrofit for high-wind areas : General ; Definitions ; Materials of construction ; Retrofitting gable end walls to enhance wind resistance -- C2. Roof deck fastening for high-wind areas : General ; Roof deck attachment for wood roofs ; Referenced standards -- Resource A: Guidelines on fire ratings of archaic materials and assemblies : Fire-related performance of archaic materials and assemblies ; Building evaluation ; Final evaluation and design solution -- Appendix : Resource A [Fire-resistance tables] : Purpose and procedure : Walls ; Columns ; Floor/ceiling assemblies ; Beams ; Doors. 
650 0 |a Standards, Engineering. 
650 0 |a Construction industry  |x Standards. 
650 0 |a Building laws. 
655 7 |a Uniform laws.  |2 lcgft 
710 2 |a International Code Council. 
994 |a C0  |b PCB 
949 |a Schlow  |b SANREF  |c 343.0786 INT  |d i  |e 39635104223479  |f 704175  |g ddc  |i Ask at Reference Desk  |j 06/30/2021 
999 |a 459826